DT80G 5-15 unversal inputs
DT85G 16-48 universal inputs
Vibrating wire support
Expandable Analogue channels using CEM20. DT80G up to 300 and DT85G up to 800
USB memory for easy data and program transfer
Flexible communications (USB, Ethernet and RS232)
Various remote connection options eg dial up modem
Supporting vibrating wire sensors the new dataTaker DT8xG GeoLogger is ideal for all geotechnical data logging applications. The dataTaker GeoLoggers have built-in vibrating wire support providing ideal data acquisition and monitoring solution for the engineer working in the geotechnical environment.
The dataTaker GeoLoggers can monitor a wide variety of geotechnical datalogging applications including slope stability, subsidence, dam wall monitoring, tunnel and mining excavation, ground water, tunnel wall monitoring and site assessment.
The DT80G and DT85G can be expanded simply by connecting dataTaker Channel Expansion Modules (CEM20) to provide 100 to 300 vibrating wire channels with thermistors.
The advanced new dataTaker DT8xG range of GeoLoggers are compatible with all major brands of geotechnical instrumentation including Slope Indicator, RST Instruments, Geokon, Soil Instruments, Roctest, AGI - Applied Geomechanics Inc.
Key Features
Standalone data logger with link to a PC
Dual channel isolation technology
User definable allocation of memory size and mode
Vibrating wire support
Expandable to 800 universal analogue channels (with CEM20's attached to a DT85)
8 digital input/output channels
12 counter inputs (4 high speed) and 2 phase encoders
Calculated measurements
SDI-12 (multiple networks)
2 serial 'smart sensor' ports
Modbus for SCADA connection
Memory of approximately 10 million data points
FTP for automatic data transfer
Web Interface
Analogue inputs supported
Thermistors
Thermocouples
PT100/PT1000
Voltage
Current
Resistance
Frequency
Vibrating wire sensors (Iclinometer/Extensometer/Piezometer/Pressure cell/ Crack meter/Tilt meter)
Bridge connections (Strain gauges/Load cells)
The DT8xG series comprises of 2 models:
DataTaker DT80G Maximum Analogue Input Capacity
- 5 Four wire Isolated/10 Two wire Isolated/15 Two wire common reference
- With 5 x CEM20's connected 100 Four wire Isolated/200 Two wire Isolated/300 Two wire common reference
DataTaker DT85G Maximum Analogue Input Capacity
- 16 Four wire Isolated/32 Two wire Isolated/48 Two wire common reference
- With 15 x CEM20's connected 300 Four wire Isolated/600 Two wire Isolated/800 Two wire common reference