GSM modem kit
- Allows connection to any Squirrel data logger remotely
- Uses GSM cellular network, ideal where no land lines are available
- Operates on dual band versions 900 MHz and 1800 MHz
- Suitable for most applications including use at urban sites, remote
- sites or in mobile applications
- Collects data at speeds up to 9600 baud
- Supplied with connecting cable, power lead and antenna
Netport RS232 to Ethernet converter
- Converts the original Squirrel data logger’s RS232 output into Ethernet
- for remote or distributed monitoring
- Allows the logger to plug in at any point on an existing Ethernet network
- making data easily accessible to anyone
- No modification to logger required
- Requires an existing Ethernet network for connection
HandyPort wireless RS232 converter
- Transmits the Squirrel data logger’s RS232 output wirelessly to a PC running SquirrelView
- Maximum range is 500m using an external antenna (100m as standard)
- Baud rates of up to 116 K; 2.4GHz frequency
- Plug and play configuration and via the in-built communications wizard in SquirrelView
- Low power consumption
GSM Modem Kit Specification
|
|
|
| Power supply (external adaptor cable included to power from optional SQ mains adapter – MPU12) |
8 to 40 VDC |
| Current consumption (when transmitting) |
<160 mA |
| Current consumption (when in standby) |
<20 mA |
| Environmental operating temperature |
-20 to +55°C |
| Sensitivity (FME antenna connector; operates on dual band versions 900MHz & 1800MHZ systems) |
108 dB |
| Communication |
V24/RS232C, 9 pin sub-D 2.4, 4.8, 9.6, 14.4 kb/s |
| LED indicators |
for CD, RI and GSM contact
|
| Dimensions |
115 x 65 x 23 mm |
| weight |
140 g |
*Grant software and data cable required (along with data enabled SIM card from mobile phone service provider)
Netport RS232 to Ethernet Converter Specification
|
|
|
Power requirements (external adapter cable included, powered from optional SQ mains adapter – MPU12) |
7.5 to 24 VDC 240 mA @ 7.5V, 75 mA @24V |
| Environmental operating temperature |
<160 mA |
| Dimensions |
28 x 42 x 65 mm |
Configuring the NetPort Ethernet to RS232 Adaptor
The main aim of this document is to specify the settings required for the NetPort to enable it to connect to your Grant logger via an Ethernet network.